ZY6288隔熱隔音材料耐燒穿試驗(yàn)機(jī)
Insulation materials resistant to wear testing machine
一、型號(hào):ZY6288Model: ZY6288
二、符合標(biāo)準(zhǔn):Conform to the standard:
GB/T25352-2010
美國聯(lián)邦航空條例FAR25
民航局運(yùn)輸類飛機(jī)標(biāo)準(zhǔn)CCAR-25-R4
GB/T25352-2010
The federal aviation regulations FAR25
The civil aviation administration of China transportation aircraft standard CCAR - 25 to R4
三、適用范圍:Scope of application:
本標(biāo)準(zhǔn)規(guī)定了隔熱隔音材料在高強(qiáng)度開放式火焰下的耐燒穿特性的試驗(yàn)方法。
本標(biāo)準(zhǔn)適用于評(píng)估隔熱隔音材料在高強(qiáng)度開放式火焰下的耐燒穿特性。
This standard stimulates the insulation materials under high strength open flame resistant to burn through the
characteristics of the test method.
This standard applies to the evaluation of insulation materials under high strength open flame burn through
resistance properties.
四、主要性能參數(shù):The main performance parameters:
1、試驗(yàn)室:試驗(yàn)室的地面長度與寬度均不應(yīng)小于3.05m。
2、燃油導(dǎo)軌可調(diào)整,使燃油噴嘴位于距離出口固定片前端8mm的位置。出口固定片應(yīng)安裝在通風(fēng)管的端部。
3、燃油:燃油宜為JP-8、Jet A或上等效的燃油。其流量應(yīng)為(0.378 0±0.012 6)L/min。如果不能獲得該燃油,4、當(dāng)
燃油標(biāo)稱流量、溫度和熱流量值符合標(biāo)準(zhǔn)要求時(shí),可采用3號(hào)噴氣燃料或其他等效的燃油。
5、校準(zhǔn)熱流計(jì)(可共用背面熱流計(jì)),為總熱流密度型、箔式Gardon熱流計(jì),量程應(yīng)為(0~22.7)W/m2,精度為指示讀數(shù)的
±3%。
6、校準(zhǔn)熱電偶直徑為3.2mm的陶瓷包封、金屬護(hù)套、接地式K型(鎳鉻-鎳鋁)熱電偶,其金屬絲直徑應(yīng)為0.511mm
7、記錄燒穿時(shí)間,即火焰穿透試樣的時(shí)間(如果有)或熱流超過2.27W/cm2的時(shí)間。
8、設(shè)備具有下列安全保護(hù)裝置:電源超載、 短路保護(hù)、控制回路過載保護(hù)。
9、采用16位板卡+微機(jī)控制,具有結(jié)構(gòu)合理、性能穩(wěn)定、操作簡便等優(yōu)點(diǎn);
10、測(cè)試期間實(shí)時(shí)顯示測(cè)量結(jié)果動(dòng)態(tài)地繪出曲線,數(shù)據(jù)可以保存、調(diào)閱和打印輸出,可直接打印報(bào)表;
1, the laboratory: the laboratory floor length and the width should not be less than 3.05 m.
2, fuel rail can be adjusted, making the fuel nozzle export fixed at the front position of 8 mm. Export stator
should be installed in the ventilation pipe end.
3, fuel oil, fuel oil appropriate for JP - 8, the Jet fuel A or international equivalent. The flow rate shall
be the (0.378 0 + / - 0.012 6) L/min. If you can't get the fuel, 4, when the nominal fuel flow rate,
temperature and heat flow values conform to the requirements of the standards, can use 3 # jet fuel or other
equivalent fuel.
(5, calibration of heat flow meter can be Shared on the back of the heat flow meter), for the total heat flux
density, foil type Gardon heat flux meter, the range should be (0 ~ 22.7 W/m2), plus or minus 3% accuracy for
the indicator reading.
6, calibrating thermocouple diameter of 3.2 mm ceramic coating, metal sheath, grounding type K type
thermocouple (nickel chrome - nickel aluminum), the wire should be 0.511 mm in diameter
7, record burn through time, namely the flame through the sample time (if any) or heat flow more than 2.27
W/cm2.
8, the equipment has the following safety protection device: power overload, short circuit protection, control
circuit overload protection.
9, 16 + microcomputer control, high precision interface card has advantages of reasonable structure, stable
performance, easy operation;
10, during testing real-time display measurement results dynamically draw perfect curve, data can be stored
permanently and read and print output, can be directly printed statement;