聯系我們
公司名稱:浩瀚色譜(山東)應用技術開發有限公司
聯系人:王經理
電話:0632-5667636
手機:15562228838(微信同號)13963221227(微信同號)
傳真:0632-5667636
郵件:1404939462@qq.com
地址:山東省滕州市(市場部和技術部);
產品詳情

產品簡介
大氣中甲烷、總烴及非甲烷總烴監測,液化石油氣,頂空進樣器,粗苯,三苯,二甲苯,環氧乙烷,三甲胺...
產品詳細介紹
大氣中甲烷、總烴及非甲烷總烴監測
大氣中甲烷、總烴及非甲烷總烴監測 詳細信息:
甲烷柱:GDX-502,2m*3mm,2m*4mm,2m*1/8
總烴柱:2m*4mm,2m*3mm,2m*1/8,硅烷化玻璃微球
滕州市浩瀚色譜儀器技術服務有限公司,采用六通閥進樣,雙填充柱、雙FID檢測器氣相色譜法,一次進樣即可測得大氣中的CH4、總烴及非甲烷總烴(NMHC)的測試數據.同時對色譜中FID檢測器中出現的氧峰初步可認定為"干擾峰",在分析中可忽略不計.方法的檢出限:CH40.03 mg/m3,總烴0.04 mg/m3,NMHC 0.06 mg/m3.變異系數:CH43.81%,總烴2.07%,NHMC 5.07%.加標回收率:CH496.1%,NHMC 96.1%~98%.
大氣中甲烷、總烴及非甲烷總烴監測 圖片:


Mo nitoring of methane, total hydrocarbons and non-methane total hydrocarbons in the atmosphere
Mo nitoring of methane, total hydrocarbons and non-methane total hydrocarbons in the atmosphere Details:
Methane column: GDX-502, 2m*3mm, 2m*4mm, 2m*1/8
Total hydrocarbon column: 2m*4mm, 2m*3mm, 2m*1/8, silanized glass microspheres
Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd. uses six-port valve injection, double packed column and double FID detector gas chromatography to measure CH4, total hydrocarbons and non-methane total hydrocarbons in the atmosphere (NMHC). Test data. At the same time, the oxygen peak appearing in the FID detector in the chromatogram can be initially identified as "interference peak", which is negligible in the analysis. The detection limit of the method: CH40.03 mg/m3, total hydrocarbon 0.04 mg / m3, NMHC 0.06 mg / m3. Coefficient of variation: CH 43.81%, total hydrocarbons 2.07%, NHMC 5.07%. Standard addition recovery: CH496.1%, NHMC 96.1% ~ 98%.
Mo nitoring of methane, total hydrocarbons and non-methane total hydrocarbons in the atmosphere
如果您覺得“GDX-502 大氣中甲烷、總烴及非甲烷總烴監測”描述資料不夠齊全,請聯系我們獲取詳細資料。(聯系時請告訴我從給覽網看到的,我們將給您最大優惠!)
本頁鏈接:http://m.521uz.com/com_haohanyiqi/sell/itemid-8669053.html
已經有1006位訪客查看了本頁.
大氣中甲烷、總烴及非甲烷總烴監測 詳細信息:
甲烷柱:GDX-502,2m*3mm,2m*4mm,2m*1/8
總烴柱:2m*4mm,2m*3mm,2m*1/8,硅烷化玻璃微球
滕州市浩瀚色譜儀器技術服務有限公司,采用六通閥進樣,雙填充柱、雙FID檢測器氣相色譜法,一次進樣即可測得大氣中的CH4、總烴及非甲烷總烴(NMHC)的測試數據.同時對色譜中FID檢測器中出現的氧峰初步可認定為"干擾峰",在分析中可忽略不計.方法的檢出限:CH40.03 mg/m3,總烴0.04 mg/m3,NMHC 0.06 mg/m3.變異系數:CH43.81%,總烴2.07%,NHMC 5.07%.加標回收率:CH496.1%,NHMC 96.1%~98%.
大氣中甲烷、總烴及非甲烷總烴監測 圖片:


Mo
Mo
Methane column: GDX-502, 2m*3mm, 2m*4mm, 2m*1/8
Total hydrocarbon column: 2m*4mm, 2m*3mm, 2m*1/8, silanized glass microspheres
Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd. uses six-port valve injection, double packed column and double FID detector gas chromatography to measure CH4, total hydrocarbons and non-methane total hydrocarbons in the atmosphere (NMHC). Test data. At the same time, the oxygen peak appearing in the FID detector in the chromatogram can be initially identified as "interference peak", which is negligible in the analysis. The detection limit of the method: CH40.03 mg/m3, total hydrocarbon 0.04 mg / m3, NMHC 0.06 mg / m3. Coefficient of variation: CH 43.81%, total hydrocarbons 2.07%, NHMC 5.07%. Standard addition recovery: CH496.1%, NHMC 96.1% ~ 98%.
Mo
如果您覺得“GDX-502 大氣中甲烷、總烴及非甲烷總烴監測”描述資料不夠齊全,請聯系我們獲取詳細資料。(聯系時請告訴我從給覽網看到的,我們將給您最大優惠!)
本頁鏈接:http://m.521uz.com/com_haohanyiqi/sell/itemid-8669053.html
已經有1006位訪客查看了本頁.
產品咨詢
相關產品推薦
相關技術文章
- icon 2018新品--非甲烷總烴專用氣相色譜儀上市
- icon 蜂王漿中10-羥基2-癸烯酸測定專用氣相色譜儀上市
- icon 2018煤氣中萘直接進樣分析專用氣相色譜儀上市
- icon 熱流祝賀《工業乙酸乙烯酯中微量甲酸測定專用氣
- icon 廢水中微量甲醇乙醇測定專用柱研制成功








